Description

顶部气相层/内部的压力测量

要求

  • 工艺过程控制
  • SIL 2/3

Description

原料缓冲罐的差压液位测量

要求

  • 液位/进料控制
  • 不易堵塞

Description

甲醛气体分离器的高低限位监测

要求

  • 泵的空转防护
  • 符合 SIL2

Description

至过滤器的甲醛进料流量测量

要求

  • 优化的分流器以降低压损
  • 多种选项(伴热、吹扫口等)

Description

缩聚反应器甲醛进料的温度测量

要求

  • 反应物的温度
  • 常规应用的保护套管材质为:1.4404 / 316L 或 1.4571 / 316Ti

Description

缩聚反应器甲醛进料的压力测量

要求

  • 耐受化学腐蚀性的材质
  • 测量长期可靠

Description

缩聚反应器的高/低限位监测

要求

  • 可选温度延长管,温度最高 +250°C/ +482°F
  • 气密性密封,适用于毒性气体

Description

缩聚反应器的高/低限位监测

要求

  • 罐底管理功能(TBM)
  • 椭圆体的形状和光滑的表面,以减少在天线上挂料

Description

连续的缩聚反应器液位测量

要求

  • 符合 SIL2
  • 输出:继电器、晶体管、两线制、NAMUR 或无触点开关

Description

缩聚反应器及其所生成的粘性脲醛树脂的温度测量

要求

  • 耐受化学腐蚀的金属保护套管
  • 接线表头防护等级可达 IP68

Description

脲醛树脂排出液的压力测量

要求

  • 耐受化学腐蚀性的材质
  • 前端齐平式过程连接

概览

Production of aldehyde derivates in the organic chemical process

Instrumentation for Monitoring and Controlling the Composition in Aldehyde Derivative Production

The widely used aminoplasts are produced by polycondensation of formaldehyde either with urea (urea resins, UF for short) or with melamine (melamine-formaldehyde resins, MF for short), which is technically obtained in large quantities from urea in preliminary processes. The process for obtaining these resins is very similar in each case: When pre-filtered urea solution is added to the formaldehyde solution, viscous UF urea resin is produced in a polycondensation reactor in an acidic environment, which is used as wood glue in chipboard production, for example. Melamine-formaldehyde resins (MF) are used for thermosetting plastics with high hardness and abrasion resistance - for example for electrical insulation or switch parts or tableware. The production process here involves the intermediate product hydroxymethylmelamine, which is obtained by adding formaldehyde to melamine at low temperatures in an aqueous solution. The final curing of the MF resins usually takes place downstream by adding fillers via polycondensation at temperatures of around 100 °C, mainly with the aid of acidic catalysts. A cross-linked duromer is then formed by splitting off water and formaldehyde.

KROHNE has an extensive portfolio of measuring instruments for the process production of aldehyde derivatives, such as aminoplasts, combined with many years of experience in this sector. To optimise the correct molar ratio of formaldehyde and urea for polycondensation, reliable pressure measurement in the feed, continuous MIN/MAX level monitoring and precise temperature measurements in the reactor are essential. Here, KROHNE contributes proven vibration level switches, highly developed radar level measuring devices and tried and tested resistance thermometers.

邮箱
联系方式